List of Tables and Formulas
Contained in LectriCalc For Handheld and Desktop Computers


Service Calculation:
• Dwelling
• Commercial

Electrical Symbols:
Nearly 200 different symbols
Formulas:
• Power
• Motors
• Ohm’s Pie
• Transformers
• Resistance
• Transformer Diagram
Tables*:  
• Std. Fuse & Breaker Sizes
• Std. Raceway Sizes
• Std. Pull/J Box Sizes
• Std. Gutter & Wireway Sizes
• Std. Switchboard/Switchgears
• Std. Busway or Busduct
• Std. Disc and Panelboard Wiring
• Std. Transformer KVA Ratings
• Bussbar Ampacity
• NEMA Enclosures
• Material Support Distances
• Vertical Conductor Supports
• Support for RMC, RNC, EMT
• Motor & Dist Connections
• Locked Rotor Code Letters
• Motor Enclosure Type
• SEC & GNDS, Riser Size
• Grounding Conductor Table
• Ampacities 310.16/.17 CU
• Messenger Wire 310.20 CU
• Ampacities 310.16/.17 AL
• Messenger Wire 310.20 AL
• Fraction to Decimal
• AWG <--> Metric Cable
• C to F/F to C
• Wire Type Insulation/Codes
• Fixture Wires
• Pressure Connectors 300 V Max
• Pressure Connectors 600 V Max
• Conduits
• Conduit Weights
• Single Phase Motors
• Three Phase Motors
• Exact K, Coated Copper
• Exact K, Uncoated Copper
• Exact K, Aluminum
• Hazardous Locations
• Locations Definitions
• Electrical First Aid
• Typical Tool List
 

* Tables presented in LectriCalc are reprinted with permission from NFPA-70-2008 National Electrical Code®, Copyright ©2007, National Fire Protection Association Quincy, MA 02169. This reprinted material is not the complete and official position of the National Fire Protection Association on the referenced subject which is represented only by the standard in its entirety. (Some tables are public domain, general references from NEMA® National Electrical Manufacturers Association, UL® Underwriters Laboratory, etc.)

 

LectriCalc v5.0 Calculations List

Ampacity Module Calculates: 

  • Derated and Maximum Ampacity
  • Minimum and Maximum OCPD (overcurrent protection)
  • Conductor Size

 Amps From Module Calculates:

  • Amperage from volts and watts
  • Amperage for single and 3-phase current from volts and KVA
  • Amperage for single and 3-phase current from volts and KW and Power Factor
  • Amperage for single and 3-phase current from volts and horsepower, Power Factor, and Efficiency

Box Size Module Calculates: 

  • Acceptable Boxes for conductors size 6 through 16, accounting for included clamps, hickeys, studs, grounds, and devices.

 Conduit Fill Module Calculates: 

  • Minimum allowable conduit for any mix of conduit type and conductor insulation and size.
  • This calculator can also show the maximum number of conductors, all the same size, allowable in any conduit.
  • The calculator supports nipples, conduit body calculations, and reports minimum allowed wire-bending space at terminals and minimum width of wiring gutters, auxiliary gutters, conduit bodies, panelboards, J-boxes, pull boxes, etc.
  • The calculator can also display the area and diameter of any conductor.

 Entergy Cost Module Calculates: 

  • Total Energy Cost per day, week, month and year based on total watts, KW cost, and hours per day.

 Find KW/HP Module Calculates: 

  • DC, Single Phase, and 3-Phase KW and HP from Amps, Volts, Efficiency, and Power Factor

 Foot Candle Calculator Calculates: 

  • Light falling on an object in ft-candles and LUX, based on lamp output in either candle power or lumens.

 Grounding Conductor Module Calculates: 

  • GEC Size for copper and aluminum from conductor size and material, and EGC Size based on amperage.

 Impedance Module Calculates: 

  • IEEE 141 Exact Voltage Drop
  • Resistance
  • Reactance
  • Effective Z (impedance)

 Motor Data Module Calculates: 

  • FLC, Conductor Size, OCP (overcurrent protection), Starter, Overload fuse, Disconnect Size, and Heater. Multi-Motor calculations are supported and Locked Rotor Current is calculated.

 Transformers, Single Phase Module Calculates: 

  • Input Watts from Output Watts and Efficiency
  • Output Watts from Input Watts and Efficiency
  • Efficiency from Input Watts and Output Watts
  • Primary and Secondary Volts from amps and KVA, or Volts and Turns
  • Primary and Secondary Amps from volts and KVA, or volts and amps
  • Primary and Secondary Turns from volts and turns or amps and turns
  • KVA from volts and amps
  • Turns ration from turns or volts

 Transformers, Three Phase Delta Module Calculates: 

  • Input volts from output volts and phase volt ratio
  • Output volts from input volts and phase volt ratio
  • Phase Volt Ratio from input volts and phase volts
  • Primary and Secondary Line VA from line volts
  • Line Volts from line VA
  • Line Amps from line volts
  • Line Amps from phase amps
  • Phase Amps from line amps
  • Line 1 Amps from line 3 amps
  • Line 3 amps from line 1 amps
  • Neutral amps from line 1 amps

 Transformers, Three Phase Wye Module Calculates: 

  • Line Volts from phase volts
  • Phase Volts from line volts
  • Neutral Current from line amps 1, 2 and 3

 Wattage/KVA Module Calculates: 

  • Single and 3-Phase Wattage and KVA for Single and 3-Phase apparent power from amps, volts, and power factor

 Wire Cost Module Calculates: 

  • Cost of wire waste based on length and size of wire and cost per ft or meter or pound or KG.

 Voltage Drop Module Includes: 

Basic and Advanced voltage drop calculators providing minimum acceptable conductor size, voltage drop, percent drop, and final operating voltage.